FCX2000-UM-251-9730 4-21
4.
OPER ATIONS
Setting the Force
Set the cutting force that is used in each of the condition numbers.
Setting range : Depends on the selected tool number.
(1) Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/4) is displayed.
(2) Press the [4] key (FORCE).
FORCE setting screen is displayed.
(3) Press the POSITION (
▲
▼
) keys and select the condition number (CONDITION No.)
(4) PPress the POSITION (▲▼) keys and increase or decrease the setting value.
(5) Conrm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to CONDITION screen (1/4).
(6) Press the [COND/TEST] key.
(7) It will return to default screen.