FCX4000-UM-251-9370 8-4
8 ELECTRICAL ADJUSTMENTS
8.2.3 The pen block was replaced
When the pen block was exchanged, perform the following adjustments.
8.9 Adjusting the Home Position
8.10 Adjusting the Pen Force
8.12 Adjusting the Tool Interval
8.13 Adjusting the Registration Mark Sensor Sensitivity
8.14 Adjusting the Offset of Registration Mark Sensor
End of Adjustment
8.2.4 The X home sensor was replaced
When the X home was exchanged, perform the following adjustments.
8.9 Adjusting the Home Position
End of Adjustment
8.2.5 The Y home sensor was replaced
When the Y home was exchanged, perform the following adjustments.
8.9 Adjusting the Home Position
End of Adjustment
8.2.6 The registration mark sensor was replaced
When the registration mark sensor was exchanged, perform the following adjustments.
8.13 Adjusting the Registration Mark Sensor Sensitivity
8.14 Adjusting the Offset of Registration Mark Sensor
End of Adjustment

Table of Contents