FCX4000-UM-251-9370 8-7
8 ELECTRICAL ADJUSTMENTS
8.4 Setting the DIP Switches
Settings for the DIP Switch on the Main Board
DIP Switch Factory Settings (Normal mode)
This setting depends on the model.
Dip Switch 1 2 3 4 5 6 7 8 Model
12345678
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF FCX4000-50
12345678
ON
OFF
ON OFF OFF OFF OFF OFF OFF OFF FCX4000-60
Note:
The NV-RAM CLEAR must perform when the dip switch setting was changed from previous settings.
NV-RAM CLEAR Function mode
All adjustment values are cleared to the default value of each model when the NV-RAM CLEAR was
performed.
Dip Switch 1 2 3 4 5 6 7 8 Model
12345678
ON
OFF
OFF OFF OFF ON OFF OFF OFF OFF FCX4000-50
12345678
ON
OFF
ON OFF OFF ON OFF OFF OFF OFF FCX4000-60
Emergency Mode
The plotter will not detect the X and Y home position at this mode.
The plotter can use temporary when the X or Y home sensor was broken.
The pen block must move to the home position manually when turn on the power for the plotter in this mode.
Dip Switch 1 2 3 4 5 6 7 8 Model
12345678
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF FCX4000-50
12345678
ON
OFF
ON OFF OFF OFF OFF OFF OFF OFF FCX4000-60