FCX4000-UM-251-9370 9-11
9 TROUBLESHOOTING
9.6 ARMS Error Messages
Error cord No. LCD Display Cause Solution
E04001
Tilt to adjust with AXIS
ALIGNMENT is too
large.
Reload the media.
E04002
It is over the setting
range of the distance
adjust.
The registration marks
printed position is not
matching to the output
data.
Some of hairlines
are printed near the
registration mark.
The registration marks
were not printed on the
10 mm from the media
edge.
Conrm the printed
registration mark positions are
matching to the output data.
Conrm no object is printed
near the registration mark.
There is not enough margin
for the registration mark from
media edge.
E04003
Failed to adjust the
sensor level.
Reection of media is too
high.
Use low reection of media.
Use low reection of laminate
if the media is laminated.
E04007
Test pattern plotting
position is not within the
plotting area for sensor
position adjustment.
Plot the test pattern to the
center of plotter.
E04009
It has exceeded
detection area while
detecting the registration
mark.
Conrm media position that is
inside of cutting area.
E04010
It has exceeded
detection area while
detecting the registration
mark for +X direction.
Conrm media position that is
inside of cutting area.
E04011
It has exceeded
detection area while
detecting the registration
mark for -X direction.
Conrm media position that is
inside of cutting area.