FCX4000-UM-251-9370 8-25
8 ELECTRICAL ADJUSTMENTS
(12) Measure the X-axis distance, Y-axis distance and the diagonal distance.
X=400 mm
Y=300 mm
XY=Diagonal distance
Input the distance which was measured for the X, the Y, and the diagonal distance.
Press the F2 key (X=) to input the X-axis distance adjustment value.
Change the value by the UP ARROW key and the DOWN ARROW key.
The unit changes when the SLOW key was pressed.
Press the ENTER key to set value.
Press the F3 key (Y=) to input the Y-axis distance adjustment value.
Change the value by the UP ARROW key and the DOWN ARROW key.
The unit changes when the SLOW key was pressed.