FCX4000-UM-251-9370 12-8
12 Target electrical component for WEEE instruction
• Removing (C) Y Relay Board
(16) Remove the four M3L6 binding head screws holding the rear Y bar end cover, and then detach it.
Rear Y bar end cover
M3L6 binding head screw
M3L6 binding head screw
(17) Disconnect all cables from the Y relay board.
Y motor power relay cable
Y motor
Y relay board
Y motor encoder cables
M3L6 binding head screw
Y exible cable
X exible cable
Y home sensor cable
(18) Remove the two M3L6 binding head screws holding the Y relay board, and then detach it.
(19) Detach Y relay board.