EasyManua.ls Logo

GRAPHTEC FCX4000 - Page 197

GRAPHTEC FCX4000
197 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FCX4000-UM-251-9370 12-11
12 Target electrical component for WEEE instruction
(28) Disconnect the high voltage board cable from the Electrostatic relay connectors.
M3L6 binding head screw
Electrostatic relay board
Electrostatic relay connector
ES power relay connector
High voltage board
(29) Detach the high voltage board.
(30) Disconnect the exible cable of electrostatic adhesion panel from the electrostatic relay board.
(31) Remove the four M3L6 binding head screws holding the electrostatic relay board.
M3L6 binding head screw
Electrostatic relay board
Electrostatic panel exible cable
Electrostatic relay connector
High voltage board
(32) Detach the electrostatic relay board.

Table of Contents