FCX4000-UM-251-9730 3-19
3.
OPERATIONS
Setting the Speed
Set the speed of the tool that is used in each of the condition numbers.
Setting range : 1 to 10 (in 1 cm/s increment), 10 to 40 (in 5 cm/s increment)
(1) Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/4) is displayed.
(2) Press the [3] key (SPEED) .
SPEED setting screen is displayed.
(3) Press the POSITION (
) keys and select the tool condition number (CONDITION No.) .
(4) Press the POSITION (▲▼) keys and increase or decrease the setting value.
You can set 1 to 10 (1-step) or 15 to 40 (5-step) (cm/s).
(5) Conrm the setting and press the [ENTER] key (SET).
Setting will be set, and it will return to CONDITION screen (1/4).
(6) Press the [COND/TEST] key.
It will return to default screen.
Setting the Force
Set the cutting force that is used in each of the condition numbers.
Setting range : Depends on the selected tool number.
(1) Press the [COND/TEST] key in the default screen.
CONDITION setting screen (1/4) is displayed.
(2) Press the [4] key (FORCE).
FORCE setting screen is displayed.
(3) Press the POSITION (
) keys and select the condition number (CONDITION No.)
(4) PPress the POSITION (▲▼) keys and increase or decrease the setting value.