GENERAL INFORMATION CU800 Service Manual
21
4. If necessary, rotate the meter ohms adjust knob until the needle and 0 mark align.
1.9.5 Clip-on ammeter
1. Clip-on ammeter (Figure 35) is the basic tool
for electrical system diagnosis which is used to
measure the current of charging system and
other electrical components work current.
2. Clip-on ammeter can measure direct current
and alternating current. Please ensure that the
instrument battery capacity is sufficient when
work.
3. When measure the current, the caliper must
seize the positive pole of the power. If seize the
negative pole mistakenly, wrong result will
appear.