83
Charging method: using a constant voltage charger
NOTE
Leave the battery unused for more than 30 minutes before measuring its open-circuit voltage.
NO
YES
NOTE
Set the charging time to a
maximum of 20 hours.
Measure the open-circuit voltage
Prior to charging.
Connect a charger and ammeter
to the battery and start charging.
Is the amperage higher than the
standard charging amperage
written on the battery?
Charge the battery until the
charging voltage reaches 15 V.
This type of battery charger
cannot charge an MF battery. A
variable voltage charger is
recommended.
Leave the battery unused for more than 30
Minutes before measuring its open-circuit
voltage.
12.8 V Charging is complete.
12.0 ~12.7 V Recharging is required.
Under 12.0 V Contact after-sales