Execute the PRO menu as follows:
Prerequisite: There is no malfunction at the FlexxPump
Prerequisite: In the SET menu, the emptying time operating mode is se-
lected
1 Touch the active surface with the magnetic peg Ü238
2 Remove the magnetic peg from the active surface once the LCD displays
"Pro" and the yellow LED lights up
3 Wait until the green LED and the LCD flash twice
4 Set the emptying time value in months
4.1 Touch the active surface with the magnetic peg Ü238
4.2 Remove the magnetic peg from the active surface once the LCD
displays the desired value and the yellow LED lights up
4.3 Wait until the green LED and the LCD flash twice
5 Set the number of strokes
5.1 Touch the active surface with the magnetic peg Ü238
5.2 Remove the magnetic peg from the active surface once the LCD
displays the desired value and the yellow LED lights up
5.3 Wait until the green LED and the LCD flash twice
The PRO menu is executed and the emptying time and number of strokes are
set.
If the FlexxPump is ready for operation (battery and lubricant cartridge are in-
serted), the newly set dispensing process starts immediately.
The counter-pressure values are displayed in bar on the LCD and the green
LED lights up during the individual strokes.
Operation
OPERATING MANUAL FlexxPump4N Lubrication
System
3422906891_v1.0_EN-US
87