6.6.5 INF menu in draining time mode
The INF menu provides information on the firmware used and the values cur-
rently set in the PRO menu in draining time mode. The operator cannot make
any changes to the values in the INF menu. The function displays the values of
the parameter in an order which cannot be changed.
The function is only available if the FlexxPump is switched "OFF". The control
system reverts to "OFF" mode after a completed function.
2x
InF
OFF
InF
n41 06 c01 400
A B C D
Fig.6-5 INF menu in draining time mode
A FlexxPump firmware version C Stroke rate value set
B Draining time value set in months D Bellow volume value set
Set up the INF menu as follows:
1 Touch magnetic surface with magnetic peg Ü238
2 Remove magnetic peg from magnetic surface as soon as the LCD shows
“INF” and the yellow LED lights up
3 Wait until the green LED and the LCD flash 2x
The FlexxPump will run the INF menu and show the values set on the LCD.
Operation OPERATING MANUAL FlexxPump4N Lubrication System