6.6.3 PRO menu in hour mode
The PRO menu is used to set the dispensing behaviour of the FlexxPump. The
operator can set the number of strokes "c" and the pause time "h". Pause
times can be set between 1…240 hours and hub strokes "c" between 1…30
strokes of 0.16cm
3
The emptying time mode is accepted as the standard at Güdel. Reference is
made to this operating mode in the lubrication recommendation and in the
lubricant quantity calculator. The details on other operating modes are to be
considered as supplementary information.
The function is only available if the FlexxPump is switched "On". The control
system reverts to "On" mode after a completed function.
The pause time "h" can be set between 1…240 hours. In doing so, values
from 1…99 are illustrated on the LCD with preset "h". Values from 100…
240 are illustrated on the LCD without preset "h".
2x
Pro
On
Pro
h01
c01
h02
2x
h04
c02
2x
c03
h03
h04
c03
c30
240
Fig.6-4 PRO menu in hour mode
Operation OPERATING MANUAL FlexxPump4N Lubrication System
3422906891_v1.0_EN-US
88