GETTING STARTED
33
Load Wire Connections
The PEL-3000(H) has input terminals on both the
front and rear panels.
Follow the procedures below for all load
connections. Please adhere to the following
precautions to ensure your safety and to protect
the unit from damage.
1. When connecting the PEL-3000(H) to the DUT,
make sure that the polarity of the connection
between the DUT and the unit matches.
2. Ensure that the maximum input voltage is not
exceeded. The maximum input voltage is
150(800) volts.
If the polarity to the input terminals is reversed, the
reverse voltage protection function is tripped. The
reverse voltage protection function is tripped when
reverse voltages greater than -0.3V are detected.
Do not touch any of the input terminals when the
voltage is applied to an input terminal.
Connecting the input terminals to the wrong polarity
can damage the DUT or the PEL-3000(H).
The front panel and rear panel input terminals are
physically connected. Any voltage that is input to one
set of terminals will also appear on the other set of
terminals.