OPERATION
61
Turning on the Load
Description
1. The load can be turned on and off by pressing
the
Load
On/
Off
key.
The
Load
On/
Off
key will turn orange when the load
is “on”.
The LOAD icon in the Main Frame status panel
will turn orange when the load is on.
Note
The load can be set to automatically turn on at
start up. See page 77.
The load can be turned on via remote control.
See the programming manual.
The load can be turned on via external control.
See page 177.
By default the load will automatically turn off if
the range or operating mode (CC, CV, CR, CP)
is changed. To disable this behavior, Set Load
Off (Mode) and Load Off (Range) to the OFF
setting. See page 78 for details.
Display
Mode
CP
IRange
H 35A
VRange
L 15V
Function
Dynamic
Configure
1.500
V
0.000
A
1.50
w
Timer1 0.025
Level2 0.00
Level1 0.00
LOADRS232
Fine
03/Oct/2018
mS
W
W
LOAD on
Shorting the Load
Description
The Short key can be used to simulate a short
circuit of the load input terminals. A short circuit is
simulated by:
Setting the current to the maximum value in CC
mode.
Setting the resistance to the minimum value in
CR mode.