Iss. a – Translation of the original version
Doc. Ref. : SOUND2.940.001
Figure 22: Microphone cable (two wires with shielding) - Connecting the 2 data bus wires
8. Slide the lower part of the cable gland towards the unit.
9. Press the shield wire against the grey plastic part.
10. Screw the lower part of the cable gland onto the fixed part.
Figure 23: Microphone cable (two wires with shielding) - Earthing on the cable gland
11. Close the unit.
5.4. POWERING UP
Before connecting the power supply, check that there is a circuit breaker and current protection
device (10 A) fitted on the line that supplies power to the SOUND2.
The protective devices (current protector and switch) must be accessible.
The product name “Sound 2 PREMIUM” (or ADVANCED) must be written legibly on the protective
device, and it must be close to the protective devices.
Power up the SOUND2 by connecting the power cable to the electrical supply.
5.5. SETTING THE SOUND 2 PARAMETERS
To be able to access the SOUND 2 parameters, the Maintenance profile must be enabled (see section
Changing profile page 40).
1. Press the “Menu” key .
2. Scroll down and go into the “Parameters” menu .