These limits can be:
− Adjusted independently in the menu Alarm > Limits
− Enabled independently, using the high or low level parameters in the digital outputs menu.
Figure 48: “Digital outputs” menu
For a digital output, a function can be selected between:
− Alarm level very high or high,
− Alarm level very low or low,
− Horn Alarm.
The output status is the actual value of the output.
Normal or inverted signal.
By default, these signals are available on terminal J2 (see Figure 4 page 16):
− 1-2 for the upper threshold,
− 3-4 for the lower threshold.
8.6.9. “System” menu
To go to the “System” menu, press the “Menu” key , then select the “System” menu and press Enter.
The software in the Maintenance profile, SOUND2 Premium version, provides access to the following 5
submenus:
Access to the general parameters
Contains all the security variables, passwords and the configuration for
the origin of the commands and definition of the points.
Gives the different software versions and the ID of the cards.
Configuration and diagnostics of the host protocol link