Page 54 / 64
Maintenance
Iss. a Original Instruction Manual
2024/01/05
Doc. Ref. : SOUND2.940.001
Parameter
Definition
Alarm list
The alarm selected with “Alarm
number” is highlighted in the first
line.
The “Up” and “Down” keys will move
the list (not the highlighted line) in
steps of 1, 10 or 50, depending on
the choice made using the three
lower softkeys.
The key opens the following
screen.
On this page, the configuration of
the selected alarm can be changed.
The current selection is highlighted
in the list, and the “Up” and “Down”
keys can be used to select another
function to be validated.
Function:
Ignore: The specified alarm is ignored.
Time Delay: Alarm message displayed but can disappear automatically if
the condition that generated the alarm is resolved within the time delay. If
the alarm is still present at the end of the time delay, the buzzer (fatal alarm
output) sounds.
Immediate: The alarm is displayed immediately.
Time delay
Represents the time after which the alarm conditions are still present. It will
be displayed and may or may not stop, depending on whether you select
Time delay or Stop time delay.
Limits: 0-240; Units: [s]; Default value = 30 s
8.6.3.4. Communication Host
This menu is used for communication between the SOUND2 and the supervision system and is used to enable