115
SETTING THE HEATING TIMES FOR HEATING CIRCUITS AND HEATING HOT
WATER
On the HDG Pelletronic control unit you can set heating times for
each heating circuit and for hot water. Per weekday, you can set a
maximum of four different heating periods. During the heating
periods, the heating circuits will be in HEATING or HOT WATER
mode.
S
ETTING THE HEATING TIME FOR
HEATING CIRCUIT 1
If more than two heating phases are required per day, no day may be
hidden. A maximum of four heating phases can be implemented. For
this, the heating phases must be divided - two on programme 1 and
two on programme 2.
Select the required level as follows:
1. Press the Enter button.
✓ The customer level is shown on the display.
2. Using the Down button, select the parameter group 10.
3. Press the Enter button.
4. Repeatedly press the Down button until Par 10-05 or 10-06
appears in the display.
✓ Either Par 10-05 or 10-06 are shown in the display.
5. Press the Enter button.
✓ The cursor flashes underneath the first day of the week Mon.
✓ The value displayed can be changed.
6. Press the Plus or Minus button.
✓ The weekday is hidden or displayed.
7. Press the Down button.
✓ The cursor flashes underneath the next weekday.
Figure 6/2 - Example programme 1