107
2. Press the Enter button.
The operating mode has been changed.
✓ The AUTOMATIC symbol lights up on the control display.
In automatic mode, the following boiler programme will run:
F
ILLING The delivery system, suction fan, stoker auger and combustion fan
are switched on.
I
GNITION The ignition fan and combustion fan are switched on.
H
EATING UP The delivery system, stoker auger and combustion fan are switched
on.
C
ONTROL The delivery system, stoker auger and combustion fan are switched
on.
B
URNING OUT The combustion fan is switched on.
(Only active if the operating temperature has been reached or if in
OFF mode.)
ADAPTING PARAMETERS
If the heating system does not work correctly in automatic mode, the
parameters in the service level will have to be adapted accordingly.
✎ See chapter “6 Using the heating system”, section “6.10 Structure
of the menus”.
PARAMETERS FOR MANUAL OPERATION
In manual operating mode, additional parameters are available
depending on the selected hydraulic system. These are primarily
used for the various mixers and pumps.
1. Switch to manual operating mode.
2. Check the functioning of the additional hydraulic system-
dependent parameters with the Plus or Minus buttons.
✓ All manual operating mode parameters have been checked.
SAVING OPERATING PARAMETERS
Once the heating system has been configured, i.e. all of the
parameters have been adapted, the set of parameters must be
stored.
1. Simultaneously press the Plus and Enter buttons.
✓ The display changes to the service level.
✓ The cursor is positioned on the parameter group “1-General”.