8 Troubleshooting – Possible faults
159
F016 Short circuit in
outdoor
temperature
sensor
Short circuit in the sensor or
sensor cable
Have the fault fixed by a
qualified electrician
F017 Outdoor
temperature
sensor open
circuit
Open circuit in sensor cable
Sensor incorrectly connected
Sensor is faulty
Have the fault fixed by a
qualified electrician
F018 Motor protection
triggered in the
delivery system
Motor overheated
Cable incorrectly connected
Have the fault fixed by a
qualified electrician
F019 Motor protection
on stoker auger
triggered
Motor overheated
Cable incorrectly connected
Have the fault fixed by a
qualified electrician
F020 Please empty ash
box
The “empty ash box” period
has elapsed
Check the ash box and empty
if necessary
Modify cleaning interval if
necessary Par. 6-12
F021 Short circuit in
upper buffer
temperature
sensor
Short circuit in the sensor or
sensor cable
Have the fault fixed by a
qualified electrician
F022 Open circuit in
upper buffer
temperature
sensor
Open circuit in sensor cable
Sensor incorrectly connected
Sensor is faulty
Have the fault fixed by a
qualified electrician
F023 Short circuit in
lower buffer
temperature
sensor
Short circuit in the sensor or
sensor cable
Have the fault fixed by a
qualified electrician
F024 Open circuit in
lower buffer
temperature
sensor
Open circuit in sensor cable
Sensor incorrectly connected
Sensor is faulty
Have the fault fixed by a
qualified electrician
F025 Lambda sensor
in heating
faulty
Open circuit in the lambda
sensor connection cable
Lambda sensor is faulty
Fuse F4 (on I/O circuit board)
faulty
Have the fault fixed by a
qualified electrician
F026 Lambda sensor is
faulty
Lambda sensor is heavily
soiled
Lambda sensor is faulty
Clean the lambda sensor
Have the fault fixed by a
qualified electrician
No. Fault Cause Remedy
Table 8/1 - Faults (continuation)

Table of Contents