DS-77xxNXI-I4/16P/4S NVR User Manual
UM DS-77xxNXI-I4/16P/4S 050619NA 104
Figure 11-2 Set Linkage Actions
2. Select the normal linkage actions, trigger alarm output, or trigger recording channel.
3. Click Apply to save the settings.
11.2.1
Configure Auto-Switch Full Screen Monitoring
When an alarm is triggered, the local monitor displays in full screen the video image from the alarming
channel configured for full screen monitoring. And when the alarm is triggered simultaneously in several
channels, you must configure the auto-switch dwell time.
1. Go to System > Live View > General.
2. Set the event output and dwell time.
Event Output: Select the output to show event video.
Full Screen Monitoring Dwell Time: Set the time in seconds to show alarm event screen. If alarms are
triggered simultaneously in several channels, their full-screen images will be switched at an interval
of 10 seconds (default dwell time).
3. Go to the Linkage Action interface of the alarm detection (e.g., motion detection, video tampering,
etc.).
4. Select the Full Screen Monitoring alarm linkage action.