DS-77xxNXI-I4/16P/4S NVR User Manual
UM DS-77xxNXI-I4/16P/4S 050619NA 110
11.6 Configure Sensor Alarms
Purpose
Set the handling action of an external sensor alarm.
11.6.1
Configure Alarm Input
1. Go to System > Event > Normal Event > Alarm Input.
2. Select an alarm input item from the list and click .
Figure 11-7 Alarm Input
3. Set the alarm input type to N.C or N.O.
4. Edit the alarm name.
5. Check the Input radio button.
6. Set the arming schedule. Refer to
Chapter 11.1 Configure Arming Schedule
.
7. Set the linkage actions. Refer to
Chapter 11.2 Configure Alarm Linkage Actions
.
8. Click Apply and follow the message box to reboot the device to have the settings take effect.