UM DS-77xxNXI-I4/16P/4S 050619NA 105
5. Select the channel(s) in Trigger Channel settings you want to make full screen monitoring.
Auto-switch will terminate once the alarm stops and go back to the live view interface.
11.2.2
Configure Audio Warning
The audio warning triggers an audible
beep
when an alarm is detected.
1. Go to System > Live View > General.
2. Enable the audio output and set the volume.
3. Go to the alarm detection (e.g., motion detection, video tampering, etc.) Linkage Action interface.
4. Select the Audio Warning alarm linkage action.
11.2.3
Notify Surveillance Center
The device can send an exception or alarm signal to the remote alarm host when an event occurs. The
alarm host refers to the PC installed with client software (e.g., iVMS-4200).
1. Go to System > Network > Advanced > More Settings.
2. Set the alarm host IP and alarm host port.
3. Go to the Linkage Action interface of the alarm detection (e.g., motion detection, video tampering,
etc.).
4. Select the Notify Surveillance Center.
11.2.4
Configure E-Mail Linkage
The system can send an e-mail with alarm information to a user or users when an alarm is detected. Refer
to
Chapter 16.7 Configure Email
for details.
1. Go to System > Network > Advanced.
2. Configure the Email settings.
3. Go to the alarm detection (e.g., motion detection, video tampering, etc.) Linkage Action interface.
4. Select the Send Email alarm linkage action.