DS-77xxNXI-I4/16P/4S NVR User Manual
UM DS-77xxNXI-I4/16P/4S 050619NA 140
Figure 15-5 USB-to-RS-232 Settings
RS-232 Connection Connect the device and the POS machine via RS-232. The RS-232 settings can
be configured in Menu > Configuration > RS-232. The Usage must be set to Transparent Channel.
Multicast Connection When connecting the device and the POS machine via Multicast protocol, set
the multicast address and port.
Sniff Connection Connect the device and the POS machine via Sniff. Configure the source address
and destination address settings.
Figure 15-6 Sniff Settings