raidcom add ldev -pool 0 -ldev_id 0x4444 -capacity 1024000 -IH1
3. Confirm that asynchronous command processing has completed.
raidcom get command_status -IH1
HANDLE SSB1 SSB2 ERR_CNT Serial# Description
00c3 - - 0 322222 -
Check command and output examples
Display the information for volume (LDEV ID: 0x4444). Confirm that the new
volume satisfies the following requirements:
The reservation attribute is set.
The volume has the same capacity as the P-VOL.
The volume is a DP-VOL.
raidcom get ldev -ldev_id 0x4444 -fx -IH1
Serial# : 322222
LDEV : 4444 VIR_LDEV : ffff
SL : 0
CL : 0
VOL_TYPE : OPEN-V-CVS
VOL_Capacity(BLK) : 1024000
NUM_PORT : 0
PORTs :
F_POOLID : NONE
VOL_ATTR : CVS : HDP
B_POOLID : 0
LDEV_NAMING :
STS : NML
OPE_TYPE : NONE
OPE_RATE : 100
MP# : 0
SSID : 0009
Used_Block(BLK) : 0
RSGID : 1
Adding an LU path to the S-VOL
Add an LU path between the port connected to the server and the S-VOL. The
host does not recognize the S-VOL, because the virtual LDEV ID has not yet
been defined to the volume for the S-VOL.