pairdisplay -g oraHA -fxce -IH0
Group   PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence,   %,P-LDEV# M CTG JID AP EM       E-Seq# E-LDEV# R/W
oraHA   dev1(L)     (CL1-A-0, 0,   0)311111  2222.P-VOL PAIR 
NEVER ,  100  4444 -   -   0  -  -            -       - L/M
oraHA   dev1(R)     (CL1-C-0, 0,   0)322222  4444.S-VOL PAIR 
NEVER ,  100  2222 -   -   0  -  -            -       - L/M
pairdisplay -g oraHA -fxce -IH1
Group   PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence,   %,P-LDEV# M CTG JID AP EM       E-Seq# E-LDEV# R/W
oraHA   dev1(L)     (CL1-C-0, 0,   0)322222  4444.S-VOL PAIR 
NEVER ,  100  2222 -   -   0  -  -            -       - L/M
oraHA   dev1(R)     (CL1-A-0, 0,   0)311111  2222.P-VOL PAIR 
NEVER ,  100  4444 -   -   0  -  -            -       - L/M
3. Using the alternate path software, resume I/O to the S-VOL.
4. If necessary, reverse the P-VOL and the S-VOL.
Related topics
• I/O modes on page 1-12
• Reversing the P-VOL and S-VOL on page 6-51
Recovering the storage systems from a primary site failure
(external system at primary site)
If a failure occurs at the primary site in a configuration with the external
storage system for the quorum disk located at the primary site, the failure
might affect the primary storage system and the external storage system
simultaneously. In this case, the GAD pair is suspended, and access to the
GAD volumes stops.
6-48
Disaster recovery of global-active device
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide