Hitachi Command Control Interface Installation and Configuration Guide. The
examples below show files on a Windows host.
Note: When specifying the serial number for VSP G1000 using CCI, add a “3”
at the beginning of the serial number. For example, for serial number 11111,
enter 311111.
HORCM file for the primary storage system: horcm0.conf
HORCM_MON
#ip_address        service         poll(10ms)     timeout(10ms)
localhost          31000           -1             3000
HORCM_CMD
\\.\PhysicalDrive0
HORCM file for the secondary storage system: horcm1.conf
HORCM_MON
#ip_address        service         poll(10ms)     timeout(10ms)
localhost          31001           -1             3000
HORCM_CMD
\\.\PhysicalDrive1
HORCM file for the virtual storage machine (SN: 11111) on the
primary storage system: horcm100.conf
HORCM_MON
#ip_address        service        poll(10ms)      timeout(10ms)
localhost         31100          -1              3000
HORCM_CMD
\\.\PhysicalDrive0
HORCM_VCMD
# redefine Virtual DKC Serial# as unitIDs
311111
HORCM file for the virtual storage machine (SN: 11111) on the
secondary storage system: horcm101.conf
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
localhost 31101 -1 3000
HORCM_CMD
\\.\PhysicalDrive1
HORCM_VCMD
# redefine Virtual DKC Serial# as unitIDs
311111
Starting CCI
After creating the CCI configuration definition files, you can start the CCI
software. Because you are not yet operating the virtual storage machine, you
4-12
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide