Before failure After failure
Pair status and I/O
mode
Pair status and I/O
mode
Volume
accessible from
the server
Volume
with latest
data
P-VOL S-VOL P-VOL
S-VOL
1
P-VOL S-VOL
PAIR (Mirror
(RL))
PAIR (Mirror
(RL))
PSUE (Local) PSUE
(Block)
OK NG P-VOL
COPY
(Mirror
(RL))
COPY
(Block)
PSUE (Local) PSUE
(Block)
OK NG P-VOL
PSUS/PSUE
(Local)
SSUS/PSUE
(Block)
PSUS/PSUE
(Local)
SSUS/PSUE
(Block)
OK NG P-VOL
PSUS/PSUE
(Block)
SSWS
(Local)
PSUS/PSUE
(Block)
SSWS
(Local)
NG NG None*
*Recover data using the P-VOL data that is not the latest, ShadowImage, Thin Image, or
other backup data.
SIM
• Primary system: DD1XYY
• Secondary system: 3A0XYY, DD1XYY, DFAXXX, DFBXXX, EF9XXX
Recovery procedure
1. Recover the S-VOL.
2. Recreate the pair.
Related topics
• Pair condition before failure on page 6-7
Recovering the S-VOL (pair status: PAIR)
The following figure shows the failure area and recovery when the pair
suspends due to an S-VOL failure.
6-16
Disaster recovery of global-active device