• Restarting CCI on page 4-43
Shutting down CCI
You must shut down both CCI instances before editing the configuration
definition files.
Procedure (Windows shown)
Shut down instance 0 and instance 1.
horcmshutdown 0 1
inst 0:
HORCM Shutdown inst 0 !!!
inst 1:
HORCM Shutdown inst 1 !!!
Editing CCI configuration definition files
The following examples show the configuration definition files for a Windows
host. Make sure to specify the actual LDEV IDs for the GAD pair volumes, not
the virtual LDEV IDs.
Note: When specifying the serial number for VSP G1000 using CCI, add a “3”
at the beginning of the serial number. For example, for serial number 11111,
enter 311111.
Example of primary HORCM file, horcm0.conf
The underlined lines below show the updates for the volumes in the sample
configuration in this chapter. Make sure to enter the information for your
system in your configuration definition files.
HORCM_MON
#ip_address        service         poll(10ms)     timeout(10ms)
localhost          31000           -1             3000
HORCM_CMD
\\.\PhysicalDrive0
HORCM_LDEV
#GRP    DEV             SERIAL          LDEV#           MU#
oraHA   dev1            311111          22:22           0
HORCM_INST
#GPR    IP ADR             PORT#
oraHA   localhost          31001
Example of secondary HORCM file, horcm1.conf
The underlined lines below show the updates for the volumes in the sample
configuration in this chapter. Make sure to enter the information for your
system in your configuration definition files.
HORCM_MON
#ip_address        service         poll(10ms)     timeout(10ms)