QRDID : 0 
QRP_Serial# : 322222 
QRP_ID : R8 
(snip)
2. Wait for more than 5 minutes after completing step 1, and then
resynchronize the pair.
a. Confirm that the I/O mode of the P-VOL is Local.
pairdisplay -g oraHA -fxce -IH0
Group   PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence,   %,P-LDEV# M CTG JID AP EM       E-Seq# E-LDEV# R/W
oraHA   dev1(L)     (CL1-A-0, 0,   0)311111  2222.P-VOL PSUE 
NEVER ,  100  4444 -   -   0  -  -            -       - L/L
oraHA   dev1(R)     (CL1-C-0, 0,   0)322222  4444.S-VOL PSUE 
NEVER ,  100  2222 -   -   0  -  -            -       - B/B
b. At the primary storage system, resynchronize the pair.
pairresync -g oraHA -IH0
c. Confirm that the P-VOL and S-VOL pair statuses change to PAIR
(Mirror (RL)).
pairdisplay -g oraHA -fxce -IH0
Group   PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence,   %,P-LDEV# M CTG JID AP EM       E-Seq# E-LDEV# R/W
oraHA   dev1(L)     (CL1-A-0, 0,   0)311111  2222.P-VOL PAIR 
NEVER ,  100  4444 -   -   0  -  -            -       - L/M
oraHA   dev1(R)     (CL1-C-0, 0,   0)322222  4444.S-VOL PAIR 
NEVER ,  100  2222 -   -   0  -  -            -       - L/M
pairdisplay -g oraHA -fxce -IH1
Group   PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence,   %,P-LDEV# M CTG JID AP EM       E-Seq# E-LDEV# R/W
oraHA   dev1(L)     (CL1-C-0, 0,   0)322222  4444.S-VOL PAIR 
NEVER ,  100  2222 -   -   0  -  -            -       - L/M
oraHA   dev1(R)     (CL1-A-0, 0,   0)311111  2222.P-VOL PAIR 
NEVER ,  100  4444 -   -   0  -  -            -       - L/M
3. Using the alternate path software, resume I/O to the volume that could
not be accessed from the server (I/O might resume automatically).
Related topics
• I/O modes on page 1-12
• Failure locations on page 6-3
•
SIMs related to GAD on page 6-6
Pair condition and recovery: path failure from the secondary
to external system
If the status of external system is normal, a failure might have occurred in a
physical path from primary or secondary system to the external system, or a
switch. Recover from the failure that occurred in the physical path or switch.
The following table shows transitions for pair status and I/O mode, the
volumes that are accessible from the server, and the location of the latest
6-36
Disaster recovery of global-active device
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide