EasyManua.ls Logo

Hitachi G1000 - Creating the S-VOL

Hitachi G1000
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
raidcom get command_status -IH1
HANDLE SSB1 SSB2 ERR_CNT Serial# Description
00c3 - - 0 322222 -
Check command and output examples
1. Confirm that volume (LDEV ID: 0x7777) is set for the pool volume of pool
(pool ID: 0).
raidcom get ldev -ldev_id 0x7777 -fx -IH1
Serial# : 322222
LDEV : 7777
SL : 0
CL : 0
VOL_TYPE : OPEN-V-CVS
VOL_Capacity(BLK) : 209715200
NUM_LDEV : 1
LDEVs : 7777
NUM_PORT : 0
PORTs :
F_POOLID : 0
VOL_ATTR : CVS : POOL
RAID_LEVEL : RAID1
RAID_TYPE : 2D+2D
NUM_GROUP : 1
RAID_GROUPs : 13-04
DRIVE_TYPE : DKR5E-J1R2SS
DRIVE_Capa : 2286717474
LDEV_NAMING :
STS : NML
OPE_TYPE : NONE
OPE_RATE : 100
MP# : 0
SSID : 0007
RSGID : 0
2. Check the pool capacity.
raidcom get dp_pool -IH1
PID POLS U(%)
AV_CAP(MB) TP_CAP(MB) W(%) H(%) Num LDEV#
LCNT TL_CAP(MB)
000 POLN 0 98196 98196 70 80 1 30583
0 0
3. Check the pool name.
raidcom get pool -key opt -IH1
PID POLS U(%) POOL_NAME Seq# Num
LDEV# H(%) VCAP(%) TYPE PM
000 POLN 0 HA_POOL 322222 1
30583 80 - OPEN N
Creating the S-VOL
Specify the volume that will become the S-VOL using the reservation
attribute and LDEV ID mapped earlier. The S-VOL must be the same size as
the P-VOL.
4-38
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide

Table of Contents

Other manuals for Hitachi G1000

Related product manuals