raidcom get command_status -IH1
HANDLE   SSB1    SSB2    ERR_CNT        Serial#     Description
00c3        -       -          0         322222     -
Check command and output examples
1. Confirm that volume (LDEV ID: 0x7777) is set for the pool volume of pool
(pool ID: 0).
raidcom get ldev -ldev_id 0x7777 -fx -IH1
Serial#  : 322222
LDEV : 7777
SL : 0
CL : 0
VOL_TYPE : OPEN-V-CVS
VOL_Capacity(BLK) : 209715200
NUM_LDEV : 1
LDEVs : 7777
NUM_PORT : 0
PORTs :
F_POOLID : 0
VOL_ATTR : CVS : POOL
RAID_LEVEL  : RAID1
RAID_TYPE   : 2D+2D
NUM_GROUP : 1
RAID_GROUPs : 13-04
DRIVE_TYPE  : DKR5E-J1R2SS
DRIVE_Capa : 2286717474
LDEV_NAMING :
STS : NML
OPE_TYPE : NONE
OPE_RATE : 100
MP# : 0
SSID : 0007
RSGID : 0
2. Check the pool capacity.
raidcom get dp_pool -IH1
PID  POLS U(%)  
AV_CAP(MB)  TP_CAP(MB) W(%) H(%) Num LDEV#  
LCNT  TL_CAP(MB)
000  POLN   0       98196       98196   70   80    1 30583     
0          0
3. Check the pool name.
raidcom get pool -key opt -IH1
PID  POLS U(%) POOL_NAME                            Seq# Num 
LDEV# H(%) VCAP(%) TYPE PM
000  POLN   0  HA_POOL                            322222   1 
30583  80       -  OPEN N
Creating the S-VOL
Specify the volume that will become the S-VOL using the reservation
attribute and LDEV ID mapped earlier. The S-VOL must be the same size as
the P-VOL.
4-38
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide