pairdisplay -g oraHA -fxce -IH1
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-C-0, 0, 0)322222 4444.S-VOL PAIR
NEVER , 100 2222 - - 0 - - - - L/M
oraHA dev1(R) (CL1-A-0, 0, 0)311111 2222.P-VOL PAIR
NEVER , 100 4444 - - 0 - - - - L/M
6. Using the alternate path software, restart I/Os from the server to S-VOLs
in the secondary storage system.
Related topics
I/O modes on page 1-12
Resolving failures in multiple locations
If failures occur in multiple locations, use the following recovery procedure:
1. Identify the failure locations from the SIMs issued by the primary and
secondary storage systems and using the SAN management software,
and then recover from the failures.
2. If data has been lost from both volumes, recover from the backup data
using ShadowImage or Thin Image volumes, or backup software.
3. If I/O is stopped, resume I/O from the server.
4. If GAD pairs are suspended, resynchronize the pairs.
If the pairs cannot be resynchronized, delete the pairs and then create
them again.
Related topics
SIMs related to GAD on page 6-6