Steps for recovery
1. Reconnect the physical path or reconfigure the SAN to recover the path
failure.
When the path is recovered, the remote path is automatically recovered.
If you recover the physical path but the remote path does not recover,
contact Hitachi Data Systems customer support.
2. Resynchronize the pair.
a. Confirm that the P-VOL I/O mode is Local.
pairdisplay -g oraHA -fxce -IH0
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-A-0, 0, 0)311111 2222.P-VOL PSUE
NEVER , 100 4444 - - 0 - - - - L/L
oraHA dev1(R) (CL1-C-0, 0, 0)322222 4444.S-VOL PSUE
NEVER , 100 2222 - - 0 - - - - B/B
b. At the primary system, resynchronize the pair.
pairresync -g oraHA -IH0
c. Confirm that the P-VOL and S-VOL pair statuses change to PAIR
(Mirror (RL)).
pairdisplay -g oraHA -fxce -IH0
Group PairVol(L/R) (Port#,TID, LU),Seq#,LDEV#.P/S,Status,
Fence, %,P-LDEV# M CTG JID AP EM E-Seq# E-LDEV# R/W
oraHA dev1(L) (CL1-A-0, 0, 0)311111 2222.P-VOL PAIR
NEVER , 100 4444 - - 0 - - - - L/M
6-26
Disaster recovery of global-active device
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide