Procedure
1. Change the attribute of port (CL3-A) on the primary storage system to
Initiator.
raidcom modify port -port CL3-A -port_attribute MCU -IH0
2. Change the attribute of port (CL4-A) on the primary storage system to
RCU Target.
raidcom modify port -port CL4-A -port_attribute RCU -IH0
3. Change the attribute of port (CL3-C) on the secondary storage system to
RCU Target.
raidcom modify port -port CL3-C -port_attribute RCU -IH1
4. Change the attribute of port (CL4-C) on the secondary storage system to
Initiator.
raidcom modify port -port CL4-C -port_attribute MCU -IH1
Use the same procedure to change the port attributes for the alternate paths.
The alternate paths are not shown in the illustration.
Check command and output examples
1. Display the port information for the primary system.
4-14
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide