Note: When specifying the serial number for VSP G1000 using CCI, add a “3”
at the beginning of the serial number. For example, for serial number 11111,
enter 311111.
Procedure
1. Add a remote connection with path group ID 0 from primary system port
(CL3-A) to secondary system port (CL3-C).
raidcom add rcu -cu_free 322222 R800 0 -mcu_port CL3-A -rcu_port
CL3-C -IH0
2. Confirm that asynchronous command processing has completed.
raidcom get command_status -IH0
HANDLE SSB1 SSB2 ERR_CNT Serial# Description
00c3 - - 0 311111 -
3. Add a remote connection with path group ID 0 from secondary system
port (CL4-C) to primary system port (CL4-A).
raidcom add rcu -cu_free 311111 R800 0 -mcu_port CL4-C -rcu_port
CL4-A -IH1
4. Confirm that asynchronous command processing has completed.
raidcom get command_status -IH1
HANDLE SSB1 SSB2 ERR_CNT Serial# Description
00c3 - - 0 322222 -
4-16
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide