Procedure
1. Change the attribute of the port (CL5-A) on the primary storage system
to External.
raidcom modify port -port CL5-A -port_attribute ELUN -IH0
2. Change the attribute of the port (CL5-C) on the secondary storage system
to External.
raidcom modify port -port CL5-C -port_attribute ELUN -IH1
Check command and output examples
1. Display port information for the primary system.
raidcom get port -IH0
PORT TYPE
ATTR SPD LPID FAB CONN SSW SL Serial#
WWN PHY_PORT
(snip)
CL5-A FIBRE ELUN AUT E4 N FCAL N 0 311111
50060e80072b6740 -
(snip)
2. Display the port information for the secondary system. Confirm that the
port attributes have been changed as intended.
raidcom get port -IH1
PORT TYPE
ATTR SPD LPID FAB CONN SSW SL Serial#
4-18
Configuration and pair management using CCI
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide