ENGLISH
DHW boost (Default for input 6)
This function allows a request for a one-time heating up of the domestic hot water temperature. The input can be sent by a push
button, a NC contact and a NO contact. This input is switched on terminals 16 and 20 of the TB2.
Common
Line
DHW Boost
input 6
16 20
Power Meter (Default for input 7)
This function is used to monitor real consumption of the system by means an external power meter device connected at this input.
The calculation method is done by measuring real consumption of the whole installation with one power meter device or 2 separate
power meter (one for indoor unit and another one for outdoor unit.
Common
Line
Power M.
input 7
16 21
Aquastat for circuit 1
Aquastat is a security accessory to control in order to prevent high water temperature entering into oor system (Circuit 1). This
devices must be connected to terminals 22 & 23 for circuit 1.
When this devices is activated because of the high temperature of the water, it stops the water pump in order to stop the ow of
water to the heating oor.
22 23
C
Second Aquastat
1
Circuit 1 (for WP)
? NOTE
For R410A models terminals 28 & 29 for circuit 2 are available.
ELECTRICAL AND CONTROL SETTINGS
PMML0575 rev.2 - 03/2022
107

Table of Contents

Other manuals for Hitachi YUTAKI RWM-2R1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI RWM-2R1E and is the answer not in the manual?

Hitachi YUTAKI RWM-2R1E Specifications

General IconGeneral
BrandHitachi
ModelYUTAKI RWM-2R1E
CategoryAir Conditioner
LanguageEnglish

Related product manuals