ENGLISH
4.4.2 YUTAKI S COMBI
RWD-(2.0-6.0)(N/R)W1E-220S(-K)
Model Power supply
Applicable voltage
Operation mode
RNC
(A)
IPT
(kW)
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RWD-2.0RW1E-220S(-K) 1~ 230V 50Hz 253 207
Without electric heater 0.5 0.06 0.63 0.06
With electric heater 13.7 3.06 13.7 3.06
With DHW tank heater 12.6 2.81 12.6 2.81
With electric and DHW tank heaters 25.6 5.81 25.6 5.81
RWD-2.0RW1E-220S(-K) 3N~ 400V 50Hz 440 360
Without electric heater 0.5 0.06 0.63 0.06
With electric heater 8.7 3.06 9.3 3.06
With DHW tank heater 12.5 2.81 12.6 2.81
With electric and DHW tank heaters 12.5 5.81 12.6 5.81
RWD-(2.5-3.0)RW1E-220S(-K) 1~ 230V 50Hz 253 207
Without electric heater 0.6 0.06 0.63 0.06
With electric heater 13.7 3.06 13.7 3.06
With DHW tank heater 12.6 2.81 12.6 2.81
With electric and DHW tank heaters 25.6 5.81 25.6 5.81
RWD-(2.5-3.0)RW1E-220S(-K) 3N~ 400V 50Hz 440 360
Without electric heater 0.6 0.06 0.63 0.06
With electric heater 8.7 3.06 9.3 3.06
With DHW tank heater 12.5 2.81 12.6 2.81
With electric and DHW tank heaters 12.5 5.81 12.6 5.81
RWD-(4.0-6.0)NW1E-220S(-K)
1~ 230V 50Hz 253 207
Without electric heater 0.6 0.08 0.65 0.08
With electric heater 26.7 6.08 26.7 6.08
With DHW tank heater 12.6 2.83 12.6 2.83
With electric and DHW tank heaters
38.7 8.83 38.7 8.83
3N~ 400V 50Hz 440 360
Without electric heater 0.6 0.08 0.65 0.08
With electric heater 17.4 6.08 18.0 6.08
With DHW tank heater 12.6 2.83 12.6 2.83
With electric and DHW tank heaters 17.4 8.83 18.0 8.83
ELECTRICAL DATA
PMML0575 rev.2 - 03/2022