11.13.3.10 Optional functions conguration
This menu allows to congure the optional functions for system, space heating or space cooling, DHW and Emergency operation.
Emergency operation:
Enable or disable emergency operation for space
heating or DHW. See detailed information below.
Heating Auto On/Off:
To stop automatically stop heating
operation when the daily average outdoor
temperature of the previous day is higher
than the dened Switch-OFF temperature.
See detailed information below.
Auto Heat/Cool:
Allows to set automatic switch over to
heating and cooling operation using the
same daily average outdoor temperature
of the previous day as in Heating auto ON/
OFF.
Smart function:
To block or limit the heat pump or increase
demand due to electricity availability. See
detailed information below.
Hot water tank:
Congure the optional functions for the
DHW. See detailed information below.