4.5 MONOBLOC SYSTEM
YUTAKI M (R32)
RASM-(2/3)VRE
Model Power supply
Applicable voltage
Operation mode
Cooling
operation
Heating
operation
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-2VRE
1~ 230V 50Hz 253 207
Without DHW tank heater 4.8 1.00 5.5 1.14 10.6 2.32
With DHW tank heater 4.8 1.00 18.8 3.89 23.1 5.07
RASM-3VRE
Without DHW tank heater 9.4 1.94 8.9 1.84 16.0 3.54
With DHW tank heater 9.4 1.94 22.2 4.59 28.5 6.29
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
YUTAKI M (R410A)
RASM-(4-6)(V)NE
Model Power supply
Applicable voltage
Operation mode
Cooling
operation
Heating
operation
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-4VNE
1~ 230V 50Hz 253 207
Without DHW tank heater 9.7 2.20 9.6 2.18 30.8 7.01
With DHW tank heater 21.7 4.95 9.6 2.18 43.3 9.88
RASM-5VNE
Without DHW tank heater 13.1 2.97 13.0 2.95 30.8 7.01
With DHW tank heater 25.1 5.72 12.9 2.95 43.3 9.88
RASM-6VNE
Without DHW tank heater 15.4 3.50 16.4 3.72 30.8 7.01
With DHW tank heater 27.4 6.25 16.3 3.72 43.3 9.88
RASM-4NE
3N~ 400V
50Hz
440 360
Without DHW tank heater 3.6 2.20 3.6 2.18 14.3 8.77
With DHW tank heater 11.4 4.95 5.0 2.18 26.8 11.65
RASM-5NE
Without DHW tank heater 4.8 2.97 4.8 2.95 14.3 8.77
With DHW tank heater 13.2 5.72 6.8 2.95 26.8 11.65
RASM-6NE
Without DHW tank heater 4.8 2.97 4.8 2.95 16.3 10.02
With DHW tank heater 12.8 5.72 6.6 2.95 28.8 12.90
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
ELECTRICAL DATA
PMML0575 rev.2 - 03/2022
30

Table of Contents