Example 3
1 Move Unit controller to the living room (use as Unit controller + Room Thermostat)
2 Wired unit controller as a Room Thermostat for Zone 1
3 Wired room sensor for Zone 2
Outdoor unit
Indoor unit
1
Living room Zone 1
Bedroom Zone 2
Order FIRST
Type
Main
Unit + Circuits
Questions Answers
Is this device attached to the unit? NO
Is this device controlling the unit? YES
Is this device used as a Room Thermostat of a zone? YES, IN BOTH ZONES
Which are the heat emitters of circuit 1? Underoor heating
Which are the heat emitters of circuit 2? Underoor heating
Which are the cool emitters of circuit 1? -
Which are the cool emitters of circuit 2? -
Do you have domestic hot water tank? NO
Do you have swimming pool? NO
Do you have boiler? NO
Do you have electric backup heater? NO
COMPLETED
? NOTE
After nishing Conguration assistant, go to Input&Outputs&Sensor menu and select which auxiliary sensor do you want to use for ambient
temperature in Zone 2.
Example: Sensor 1: C2 Ambient
REF Access Description Default Value Selected value
Auxiliary Sensors
Taux1 Sensor 1 (Taux1) Two3 (if Boiler) C2 Ambient
Taux2 Sensor 2 (Taux2) Swimming pool (if SWP existing) -
Taux3 Sensor 3 (Taux3) Outdoor Sensor -
UNIT CONTROLLER (PC-ARFH2E)
PMML0575 rev.2 - 03/2022
184