ENGLISH
List of available outputs:
Deactivated
SWP 3WV: (Fixed in output 1 if swimming pool is enabled): Signal control of the 3-way valve of the swimming pool.
Water pump 3: (Fixed in output 2 if hydraulic separator or buffer tank is installed): Signal control of the water pump for hydraulic
separator or buffer tank.
Boiler: (Fixed in input 3 if boiler is enabled): Signal control of the boiler.
Solar Pump: (Fixed in input 4 if solar pump is enabled): Signal control of the solar pump.
Alarm: (By default in output 5):Signal is active if there is an alarm.
Operation: (By default in output 6): Signal active in case Thermo ON in any condition.
Cooling: (By default in output 7): Signal active when space cooling is operating.
Dem-ON C1: (By default in output 8): Signal active when there is Demand in circuit 1.
Heating: Signal active when space heating is operating.
DHW: Signal active when DHW is operating.
Solar overheat: Signal is active when solar overheat (only when solar combination status is total control)
Defrost: Signal active when outdoor unit is defrosting.
DHW Re-circulation: Signal active depending on option selected at chapter Circuit pump.
Fan 1 Low: Signal is active when fan coil speed selected for Circuit 1 is set to Low.
Fan 1 Medium: Signal is active when fan coil speed selected for Circuit 1 is set to Medium.
Fan 1 High: Signal is active when fan coil speed selected for Circuit 1 is set to High.
Fan 2 Low: Signal is active when fan coil speed selected for Circuit 2 is set to Low
Fan 2 Medium: Signal is active when fan coil speed selected for Circuit 2 is set to Medium.
Fan 2 High: Signal is active when fan coil speed selected for Circuit 2 is set to High.
Constant Heating: Signal is active in case operation mode of LCD controller is set to Heating.
Constant Cooling: Signal is active in case operation mode of LCD controller is set to Cooling.
List of available sensors:
Deactivated
Two3: (Fixed in sensor 1 if boiler is installed): Use this sensor to monitor water temperature when boiler is used.
Swimming Pool: (Fixed in sensor 2 if swimming pool is installed): Use this sensor when swimming pool is used in order to
monitor swimming pool temperature.
Solar panel sensor: Use this sensor when Total control is congured to monitor Solar Panel temperature.
C1 + C2 Ambient: Use this sensor when auxiliary ambient temperature sensor is used for C1 and C2.
C1 Ambient: Use this sensor when auxiliary ambient temperature sensor is used for C1.
C2 Ambient: Use this sensor when auxiliary ambient temperature sensor is used for C2.
Outdoor sensor (NTC): (By default sensor 3) To connect to the controller an auxiliary outside temperature sensor in case the
heat pump is located in a position not suitable for this measurement.
UNIT CONTROLLER (PC-ARFH2E)
PMML0575 rev.2 - 03/2022
227

Table of Contents

Other manuals for Hitachi YUTAKI RWM-2R1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI RWM-2R1E and is the answer not in the manual?

Hitachi YUTAKI RWM-2R1E Specifications

General IconGeneral
BrandHitachi
ModelYUTAKI RWM-2R1E
CategoryAir Conditioner
LanguageEnglish

Related product manuals