133
System MMI Pack (Room unit and RF receiver)
SMGB0066 rev.0 - 12/2009
Controller pack
Service Manual
4
WhilestillintheTestMode,theRoomUnitshouldbelocatedtakingthefollowingintoconsiderationandreviewingthe
illustrations below:
Find a suitable location where the signal transmission is reliable. Reliable transmission is indicated when the RF 1.
ReceiverisashingthegreenLEDevery6seconds.
Install the 2. EITHER on the wall using the wall bracket OR attach the optional table stand as shown in below.
Exit the Test Mode by pressing the 3.
or button.
• TheRoomUnitshouldbeinstalledinanopenspaceforbestperformanceasitisaradiofrequencydevice.
• Leaveatleast30cmdistancefromanymetalobjectsincludingwallboxesandatleast1meterfromanyother
electricalequipmentasradio,TV,PCetc.
• Donotmountontometalwallboxes.
• ItisrecommendedthattheRFReceiverisfullyinstalled.
IntheeventofanRFcommunicationsloss,theLEDontheRFReceiverwillindicatewhichtypeoffaulthasoccurred.
• IfthereisacommunicationsfaultbetweentheRFReceiverandtheRoomUnit,thentheLEDontheRFReceiverwill
ashredfor0.1secONeverythreeseconds.
• IfthereisafaultincommunicationsbetweentheboilerorSystemController,thentheLEDontheRFReceiverwillash
3 times quickly and then be off for three seconds.
• IfthereismorethanoneRoomUnitinstalled,asinmulti-zonesystemsforexample,andcommunicationsislostwithone
zone,thentheredLEDontheRFReceiverwillashtwotimesquicklyandthenbeofffortwoseconds.
• IfthereismorethanoneRoomUnitinstalled,asinmulti-zonesystemsforexample,andcommunicationsislostwith
bothzones,thentheredLEDontheRFReceiverwillashoncefor0.1secON,and0.9secOFF.
Oncethefaultydevicehasbeenidentied,replaceasnecessaryandfollowthere-bindingprocedureasdescribedinsection
Binding / Rebinding Procedure.