65
Accessories electrical installation
SMGB0066 rev.0 - 12/2009
Electrical wiring
Service Manual
3
The tanks must be with a DHWT temperature control thermostat and an all-pole limiter thermostat (the setting of these 
two components must be compatible with the design parameters of storage tanks). The sensors must always be located 
at a higher level than the electric heater element.
Werecommendinstallingappropriatesafetydevices(temperaturesafetydevice,safetylevelforheatingliquidsby
naturalconvection,owsafetydeviceforliquidsincirculation,etc.).
DHWT(200/300)S-2.5H1E
 
To terminal 5 and 6 of the control panel
Tothetopange
To earth terminal of the control panel
Flange
Heater
Seal
Washers
Screws
Studs
Nuts
Metal protective casing
Screws M6
Panel
Screws M4
Wires
Earth Wire
DHWT(200/300)E-2.5H1E
 
To terminal 5 and 6 of the control panel
Tothetopange
To earth terminal of the control panel
Flange
Heater
Seal
Nuts
Nylon bushing
Nylon washers
Metalic washers
Metal protective casing
Screws M6
Panel
Screws M4
Wires
Earth Wire
This sub-chapter shows the electrical wiring diagram for each unit of the Yutaki series.