Controller pack
Service Manual
4
One heating source (electric Heat Pump)
One energy source (electric Heat Pump and electric heater)
Two heating sources (electric Heat Pump and gas/oil Boiler)
Outside Temperature Compensated Control
Domestic Hot Water
The main heating loop controlled by the System Controller.
The extension mixed heating loop controlled by the Extension Controller.
Supply Water Temperature
Return Water Temperature
DHW Temperature
Outside (external) Air Temperature
Mixed Water Temperature
Room Temperature
V
Mixing Valve Position
Fault status
Overall system supply setpoint
S1
Zone 1 supply setpoint
SR1
Zone 1 room temperature setpoint
Zone 2 supply setpoint
DHW setpoint
DHW supply setpoint
TheSystemControllercanbeusedforseveraldifferenthydraulicsystemcongurations,includingmono-valentsystems,
mono-energeticsystemswithauxiliaryelectricheater,andbi-valentsystemswithgas/oilboiler.Thehydraulicsystem
congurationshouldbeselectedbysettingtheparameterCONF.
CONF 1
Mono-valent System
()
Heat Pump only
Direct Circuit
CONF 2
Mono-Energetic System
()
Heat Pump and Electric Heater
Direct Circuit
CONF 3
Bi-Valent Parallel System
()
Heat Pump and Boiler
Direct Circuit
CONF 4
Bi-Valent Series System
Heat Pump and Boiler
Mixing Circuit
CONF 5
Bi-Valent Parallel System
()
Heat Pump and Boiler
Mixing By-pass Circuit