Command-Specific Response Codes
Code Class Description
0 Success No Command-Specific Errors
1 Undefined
2 Error Invalid Selection
3 Error Parameter Too Large
4 Error Parameter Too Small
5 Error Too few data bytes received
6 Error Transmitter Specific Command Error
7 Error Write Protect Mode
8-15 Undefined
16 Error Access Restricted
17-31 Undefined
32 Error Busy
33-127 Undefined
Command #179: Read Alarm, Warning State - Latch/Unlatch
Reads Alarm, Warning State - Latch/Unlatch.
Request Data Bytes
Byte Format Description
None
Response Data Bytes
Byte Format Description
0 Enum Alarm1
1 Enum Alarm2
2 Enum Fault
3 Enum Warning
Command-Specific Response Codes
Code Class Description
0 Success No Command-Specific Errors
1 Undefined
2 Error Invalid Selection
3 Error Parameter Too Large
4 Error Parameter Too Small
5 Error Too few data bytes received
6 Error Transmitter Specific Command Error
7 Error Write Protect Mode
8-15 Undefined
16 Error Access Restricted
17-31 Undefined
32 Error Busy
33-127 Undefined