Vuquest 3320g User Guide 153
U - Update Tries
This sets the maximum number of frames the scanner should take to reach the D - 
Delta for Acceptance. Update Tries is only available when using Photo Style (1P). 
(Default = 6)
nURange:  0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A setting 
of 75% means 75% of the pixels are at or below the target white value, and 25% of 
the pixels are above the target white value. Altering this setting from the default is 
not recommended under normal circumstances. To alter grayscale values, W - 
Target White Value should be used. (Default = 50)
n% Range: 1 - 99
Step 2 - Ship a Picture Using IMGSHP
Image Ship - IMGSHP
An image is taken whenever the button is pushed, or when the Image Snap 
(IMGSNP) command is processed. The last image is always stored in memory. You 
can “ship” the image by using the IMGSHP command. 
The image ship commands have many different modifiers that can be used to 
change the look of the image output. Modifiers affect the image that is 
transmitted, but do not affect the image in memory. Any number of modifiers may 
be appended to the IMGSHP command. For example, you can use the following 
command to snap and ship a bitmap image with gamma correction and document 
image filtering: IMGSNP;IMGSHP8F75K26U 