Vuquest 3320g User Guide 47
Character Deactivation Mode
If you have sent a character from the host to trigger the scanner to begin scanning,
you can also send a deactivation character to stop scanning. Scan the following On
barcode to use character deactivation, then use Deactivation Character (following)
to select the character you will send from the host to terminate scanning. Default =
Off.
End Character Activation After Good Read
After a barcode is successfully detected and read from the scanner, the
illumination can be programmed either to remain On and scanning, or to turn Off.
When End Character Activation After Good Read is enabled, the illumination turns
Off and stops scanning after a good read. If you scan Do Not End Character
Activation After Good Read, the illumination remains On after a good read. Default
= End Character Activation After Good Read.
Character Activation Timeout
You can set a timeout for the length of time the illumination remains On and
attempting to decode barcodes when using Character Activation Mode. Set the
length (in milliseconds) for a timeout by scanning the following barcode, then
setting the timeout (from 1-300,000 milliseconds) by scanning digits ffrom the
Programming Chart, beginning on page 222, then scanning Save. Default = 30,000
ms.
Do Not End Character
Activation After Good Read
* End Character Activation
After Good Read
Character Activation Timeout