EasyManuals Logo

HP MSM7XX Reference Guide

HP MSM7XX
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
CLI commands
snmp-server trap syslog-severity
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server trap syslog-severity
Set the severity level of syslog messages that will trigger a trap.
no snmp-server trap syslog-severity
Do not send this trap.
snmp-server
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server
Enables the SNMP agent.
no snmp-server
Disables the SNMP agent.
snmp-server access port-1
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server access port-1
Enables SNMP access on the downstream port.
no snmp-server access port-1
Blocks SNMP access on the downstream port.
snmp-server allow
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server allow <ip address>/<mask>
Adds a host to the list of IP address from which access to the SNMP interface is permitted.
no snmp-server allow <ip address>/<mask>
Removes a host from the list of IP address from which access to the SNMP interface is permitted.
Parameters
<address> IP address.
</mask> Subnet mask in CIDR format. Specifies the number of bits in the mask.
snmp-server chassis-id
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server chassis-id <name>
Specifies a name to identify the service controller. By default, this is set to the serial number of the
service controller.
no snmp-server chassis-id
Deletes the system name.
2-23

Table of Contents

Other manuals for HP MSM7XX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSM7XX and is the answer not in the manual?

HP MSM7XX Specifications

General IconGeneral
BrandHP
ModelMSM7XX
CategoryController
LanguageEnglish

Related product manuals