CLI commands
snmp-server trap syslog-severity
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server trap syslog-severity
Set the severity level of syslog messages that will trigger a trap.
no snmp-server trap syslog-severity
Do not send this trap.
snmp-server
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server
Enables the SNMP agent.
no snmp-server
Disables the SNMP agent.
snmp-server access port-1
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server access port-1
Enables SNMP access on the downstream port.
no snmp-server access port-1
Blocks SNMP access on the downstream port.
snmp-server allow
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server allow <ip address>/<mask>
Adds a host to the list of IP address from which access to the SNMP interface is permitted.
no snmp-server allow <ip address>/<mask>
Removes a host from the list of IP address from which access to the SNMP interface is permitted.
Parameters
<address> IP address.
</mask> Subnet mask in CIDR format. Specifies the number of bits in the mask.
snmp-server chassis-id
Supported on: MSM710 MSM730 MSM750 MSM760 MSM765zl
snmp-server chassis-id <name>
Specifies a name to identify the service controller. By default, this is set to the serial number of the
service controller.
no snmp-server chassis-id
Deletes the system name.